Mobile C-arms divide into two generations, and that single distinction matters more than any other specification on the datasheet. This guide compares the Perlove mobile C-arm systems we distribute in the Philippines and explains what actually separates them.
The distinction that decides everything: intensifier or flat panel
- An image intensifier converts X-rays to light through a vacuum tube. It is the established, lower-cost technology, and it remains entirely adequate for orthopedic and general surgical work.
- A dynamic flat-panel detector captures the image digitally. It gives a larger usable imaging area for the same nominal size, no geometric distortion at the edges of the field, and no degradation over the life of the tube.
On the PLX118C and PLX119C the detector is 30 cm × 30 cm, and the manufacturer states the imaging area is increased by roughly 100% compared with a conventional intensifier. If you are imaging a spine or a pelvis, that field of view is the difference between one acquisition and several.
Generator power tells you which procedures the system is built for
Output separates the range more honestly than the model number does:
Not sure which model fits? Tell us your daily workload and we will name the ones that do.
Ask our engineersAuthorized distributor · installation, training, calibration and parts nationwide
- 5.0 kW — extremity, orthopedic and general surgical imaging (PLX112B1, PLX112C1, PLX118F, PLX118F-Plus).
- 12 kW — heavier general surgical workloads (PLX7000B, 40–125 kV, 4–160 mA).
- 25 kW — vascular and interventional work, where penetration through larger body habitus and sustained fluoroscopy matter (PLX119C, PLX7100A at 5–200 mA).
A 5 kW generator will not do vascular work no matter how good the detector is, and a 25 kW system is more machine than an orthopedic theatre needs.
Comparison
The machines compared here
Tap any machine for full specifications and a quotation.












| Unit | Model | Imaging | Generator | kV / mA | C-arm opening | Notes |
|---|---|---|---|---|---|---|
![]() |
PLX112B1 | Image intensifier | 5.0 kW | 40–120 kV / 4–100 mA | 760 mm (arc depth 640 mm) | Motorised C-arm, 19″ LCD |
![]() |
PLX112C1 | Image intensifier | 5.0 kW | 40–120 kV / 3–100 mA | 760 mm (arc depth 640 mm) | Focus-to-screen 960 mm, 19″ LCD workstation |
![]() |
PLX116B1 | Image intensifier | not stated | not stated | not stated | All-in-one, cable-free single mobile unit |
![]() |
PLX7000B | Image intensifier | 12 kW | 40–125 kV / 4–160 mA | 860 mm | Larger opening for bigger patients |
![]() |
PLX118F | Flat panel 9″ × 9″ | 5.0 kW | 120 kV / 4–100 mA | 800 mm (arc depth 660 mm) | GPU-based real-time processing |
![]() |
PLX118F-Plus | Flat panel 9″ × 9″ | 5.0 kW | 120 kV / 4–100 mA | 800 mm (arc depth 660 mm) | Adds last-image hold, storage, sharpening |
![]() |
PLX118WF | Flat panel 9″ × 9″ | not stated | not stated | not stated | Dual-monitor trolley; wider field than a 9″ intensifier |
![]() |
PLX118WF-Plus | Flat panel | not stated | not stated | not stated | Mobile monitor trolley with integrated workstation |
![]() |
PLX118C | Flat panel 30 cm × 30 cm | not stated | not stated | not stated | Imaging area approx. 100% larger than a conventional intensifier |
![]() |
PLX119C | Flat panel 30 cm × 30 cm | 25 kW | 120 kV / 100 mA | not stated | All-in-one gantry and workstation in one frame |
![]() |
PLX7100A | Flat panel | 25 kW | 125 kV / 5–200 mA | not stated | Highest tube current in the range |
![]() |
PLX7500 | Flat panel, 3D | not stated | not stated | not stated | 3D acquisition — a different class of system |
Where a figure is not published for a configuration it is shown as “not stated” rather than estimated. Ask us and we will confirm it against the manufacturer's current specification sheet.
All-in-one or trolley?
The PLX116B1 and PLX119C integrate the gantry and the imaging workstation into a single cable-free unit. That means one thing to move, one thing to position, and no cable run across a theatre floor. The PLX118WF instead uses a separate dual-monitor trolley, which lets the surgeon and the radiographer look at different images at the same time. Neither is better in the abstract — it depends on your theatre layout and how many people need to see the screen.
What is included
Osyali Construction and Trading, Inc. is an authorized distributor of Mindray and Perlove in the Philippines. Every system is supplied with nationwide delivery, installation and commissioning, operator orientation, and after-sales service and calibration.
Specifications above are the manufacturer's published figures for each configuration. Final configuration, room and power requirements are confirmed in writing before order.
Next step
Tell us your workload and what you test for — we will come back with the configuration that fits, and the room-planning figures to go with it. No obligation.
Get a configuration and quotationGet a quotation for your laboratory
Tell us the facility and what you are sizing for. Our engineers quote the configuration that fits your workload — not the largest unit. Delivery, installation and after-sales service are included nationwide in the Philippines.