Mindray CAL6000 Hematology Analyzer with Slide Maker & Stainer

Mindray CAL6000 Hematology Analyzer with Slide Maker & Stainer

Price on request
Skip to product information
Mindray CAL6000 Hematology Analyzer with Slide Maker & Stainer

Official distributor · Mindray

Mindray CAL6000 Hematology Analyzer with Slide Maker & Stainer

Genuine unit & warranty Nationwide delivery & install Calibration & service
  • Automated CBC and blood-smear workflow in one integrated line, reducing manual slide handling for hospital and reference labs
  • Configurable throughput up to 220 tests/hour and 120 slides/hour, scalable from single-analyzer to dual-analyzer lines
  • 29 reportable + 20 research parameters per sample, with NRBC and basophil results included at no extra reagent cost
  • Low sample volume (80 uL whole blood, 35 uL capillary) reduces draw volume and reagent consumption
  • Local authorized-distributor installation, training, and after-sales engineering support from Osyali/Medisense

Request a Quote

Official pricing · warranty · nationwide installation

No obligation · Genuine units only · A real person replies fast

or
Chat on WhatsApp or email us directly →
Included with every unit

You get a partner, not just a machine

Delivery & installationOn-site setup by our engineers
Operator trainingYour staff, fully onboarded
CalibrationCommissioned to spec
Preventive maintenanceScheduled PMS to protect uptime
Genuine spare partsAuthentic components only
Nationwide serviceSupport across the Philippines
Official warrantyGenuine units onlyPH-wide support
Specifications & details+

The Mindray CAL 6000 is a bench-top cellular analysis line that combines one or two Mindray 6-part-differential auto hematology analyzers (BC-6000 or BC-6200) with the SC-120 Slide Maker & Stainer on a single automated track. It is built for hospital laboratories, clinical reference labs, and diagnostic centers in the Philippines that need automated complete blood count (CBC) analysis together with automated blood-smear preparation and staining in one space-saving footprint.

By integrating sample analysis and slide making/staining, the CAL 6000 is intended to streamline hematology workflow, reduce manual smear handling, and support consistent slide quality for laboratories with moderate-to-high daily sample volumes. The line is offered in several fixed configurations (analyzer-only or analyzer plus SC-120, single or dual analyzer) so throughput can be matched to laboratory volume.

Key Features & Specifications

  • Integrated cellular analysis line: pairs one or two BC-6000 / BC-6200 auto hematology analyzers with the SC-120 Slide Maker & Stainer on a connecting track.
  • Throughput (configuration-dependent): the flagship dual-analyzer configuration runs up to 220 CBC+DIFF tests per hour with the SC-120 processing up to 120 stained slides per hour; single-analyzer configurations run up to 110 tests per hour. Exact throughput depends on the model/configuration ordered.
  • Sample loading: large loading area holds up to 100 sample tubes at the same time across the line (each individual BC-6000/BC-6200 autoloader holds up to 50 tubes).
  • Patented two-way (bidirectional) loading track on the first analyzer for fast, smart distribution of workload across the line.
  • Automated rerun / reflex / repeat: when a sample's results meet preset criteria, the autoloader can automatically return the sample rack for a rerun, reflex (add-on test), or repeat; re-exam rules can be defined by patient age, gender, department, historical result, and similar criteria.
  • STAT priority: emergency samples can be loaded ahead of routine samples (single-sample STAT button or STAT-batch loading) to shorten turnaround time.
  • Analyzer technology (BC-6000): SF Cube technology (Scatter, Fluorescence, three-dimensional analysis) with flow cytometry for the 6-part WBC differential plus NRBC; DC (electrical impedance) method for RBC and PLT; cyanide-free reagent for hemoglobin.
  • Reportable parameters: 29 reportable parameters plus 20 research parameters on whole blood; NRBC and basophil results generated in routine CBC without additional reagent. Body-fluid mode adds 7 reportable and 11 research parameters (Peritoneal, Pleural, Cerebrospinal, and Synovial fluid).
  • Analyzer sample volume: 80 µL whole blood (closed-tube, autoloader) for CBC+DIFF with NRBC; 35 µL capillary blood (closed-tube); 20 µL predilute.
  • SC-120 slide loading: loads up to 150 blank slides at a time, plus up to 10 cassettes (10 slides per cassette) for staining/output; supports Wright, Wright-Giemsa, and May-Grunwald-Giemsa stain protocols with stain recycling up to 20 times.
  • SC-120 micro-sample: STAT/micro-sample position handles samples requiring as little as 40 µL of blood; standard autoloader/on-track sample volume is 200 µL.
  • Sapphire glass blood spreader that automatically adjusts blood volume, spreading speed, and angle to the sample's consistency.
  • Heat drying before and after staining to support staining quality and reduce contamination risk.
  • Operation: touchscreen interface (7.8" on the SC-120), also operable via PC, with labXpert laboratory management software as standard for sample validation, re-exam rule management, and review.

What's Included, Installation & Service

  • One or two BC-6000 / BC-6200 auto hematology analyzers and, where included, the SC-120 Slide Maker & Stainer on an integrated track, with starter reagents and consumables per the configuration ordered.
  • Configuration options (single or dual analyzer; with or without SC-120) are available to match laboratory sample volume and bench space; an optional connecting workbench/cabinet is available per configuration.
  • As an authorized Mindray distributor in the Philippines, Medisense (Osyali Construction & Trading, Inc.) provides delivery, installation, and operator orientation.
  • After-sales engineering support is available, including preventive maintenance, calibration, repair, and genuine spare parts.

For pricing in Philippine Peso (PHP), configuration advice, and a formal quotation, contact Medisense. Final specifications depend on the analyzer model and configuration selected.

Dimensions

Standalone analyzer unit (BC-6000): 672 mm (W) x 826 mm (D) x 695 mm (H); weight approx. 87.5 kg. Assembled CAL 6000 line, by configuration: dual-analyzer only (BC-6000+BC-6000 or BC-6200+BC-6200) 1340 x 1027 x 728 mm, approx. 350 kg; single analyzer + SC-120 (e.g., BC-6000+SC-120) 2303 x 1027 x 728 mm, approx. 480 kg; dual analyzer + SC-120 (the flagship CAL 6000 211 line) 2968 x 1027 x 728 mm, approx. 630 kg. SC-120 as a standalone unit: main unit 845 x 910 x 610 mm, approx. 200 kg, plus a separate pneumatic unit 305 x 475 x 425 mm, approx. 25 kg. Exact footprint depends on the configuration ordered and is confirmed at quotation.

Supplied by Osyali Construction & Trading, Inc., an authorized Mindray distributor in the Philippines. Installation, training, and after-sales service available.

You may also like