{"product_id":"mindray-cal6000","title":"Mindray CAL6000 Hematology Analyzer with Slide Maker \u0026 Stainer","description":"\u003cp\u003eThe \u003cstrong\u003eMindray CAL 6000\u003c\/strong\u003e is a bench-top cellular analysis line that combines a Mindray 5-part-differential auto hematology analyzer (BC-6000 or BC-6200) with the \u003cstrong\u003eSC-120 Slide Maker \u0026amp; Stainer\u003c\/strong\u003e on a single automated track. It is built for hospital laboratories, clinical reference labs, and diagnostic centers in the Philippines that need automated complete blood count (CBC) analysis together with automated blood-smear preparation and staining in one compact, space-saving footprint.\u003c\/p\u003e\n\n\u003cp\u003eBy integrating sample analysis and slide making\/staining, the CAL 6000 is intended to streamline hematology workflow, reduce manual smear handling, and support consistent slide quality for laboratories with moderate-to-high daily sample volumes.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated cellular analysis line:\u003c\/strong\u003e pairs a BC-6000 \/ BC-6200 auto hematology analyzer with the SC-120 Slide Maker \u0026amp; Stainer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThroughput:\u003c\/strong\u003e up to 220 tests per hour and up to 120 slides per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample loading:\u003c\/strong\u003e large loading area holds up to 100 sample tubes at the same time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePatented two-way loading track\u003c\/strong\u003e for distribution of workload across the line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated rerun \/ reflex:\u003c\/strong\u003e when results meet preset criteria, the sample rack can step back automatically for a rerun or reflex test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSTAT priority:\u003c\/strong\u003e emergency samples can be loaded ahead of routine samples to shorten turnaround time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalyzer technology (BC-6000):\u003c\/strong\u003e SF Cube technology (Scatter, Fluorescence, three-dimensional analysis) with flow cytometry for the 5-part WBC differential plus NRBC; DC (impedance) method for RBC and PLT; cyanide-free reagent for hemoglobin.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReportable parameters:\u003c\/strong\u003e 29 reportable parameters plus 20 research parameters; NRBC and basophil results without additional reagent.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalyzer sample volume:\u003c\/strong\u003e approximately 80 µL whole blood for a CBC+DIFF with NRBC (about 35 µL capillary blood).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSC-120 slide capacity:\u003c\/strong\u003e loads up to 180 slides at a time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSC-120 micro-sample:\u003c\/strong\u003e STAT position handles micro-samples requiring as little as 40 µL of blood.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSapphire glass blood spreader\u003c\/strong\u003e that automatically adjusts blood volume, spreading speed, and angle to the sample's consistency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat drying before and after staining\u003c\/strong\u003e to support staining quality and reduce contamination risk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e touchscreen interface, also operable via PC, with laboratory management software for sample validation and review.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat's Included, Installation \u0026amp; Service\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBC-6000 \/ BC-6200 auto hematology analyzer and SC-120 Slide Maker \u0026amp; Stainer on an integrated track, with starter reagents and consumables per the configuration ordered.\u003c\/li\u003e\n\u003cli\u003eConfiguration options are available to match laboratory sample volume and bench space.\u003c\/li\u003e\n\u003cli\u003eAs an authorized Mindray distributor in the Philippines, Medisense (Osyali Construction \u0026amp; Trading, Inc.) provides delivery, installation, and operator orientation.\u003c\/li\u003e\n\u003cli\u003eAfter-sales engineering support is available, including preventive maintenance, calibration, repair, and genuine spare parts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor pricing in Philippine Peso (PHP), configuration advice, and a formal quotation, contact Medisense. Final specifications depend on the analyzer model and configuration selected.\u003c\/p\u003e\u003ch3\u003eDimensions\u003c\/h3\u003e\u003cp\u003eAnalyzer unit (BC-6000): 672 mm (W) x 826 mm (D) x 695 mm (H); weight approx. 87.5 kg. The complete CAL 6000 line (analyzer + SC-120 Slide Maker \u0026amp; Stainer on a connecting track) requires additional bench space; total assembled dimensions vary by configuration and are confirmed at quotation.\u003c\/p\u003e\u003cp\u003eSupplied by \u003cstrong\u003eOsyali Construction \u0026amp; Trading, Inc.\u003c\/strong\u003e, an authorized Mindray distributor in the Philippines. Installation, training, and after-sales service available.\u003c\/p\u003e","brand":"Mindray","offers":[{"title":"Default Title","offer_id":53334371959078,"sku":null,"price":23205000.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/1906\/7430\/files\/mindray-cal6000_0.jpg?v=1781257134","url":"https:\/\/medisenselab.com\/products\/mindray-cal6000","provider":"Medisense laboratory","version":"1.0","type":"link"}